Thursday, September 22, 2011

Pediatric, Infant, Child Pads OnSite & Home AED

!±8±Pediatric, Infant, Child Pads OnSite & Home AED

Brand : Philips
Rate :
Price : $83.05
Post Date : Sep 22, 2011 13:52:58
Usually ships in 1-2 business days



Pediatric Electrode Cartridge for Philips HeartStart HS1 OnSite AED

Catalog Wet Shaving Razors

Saturday, September 17, 2011

AED Maintenance Tips

!±8± AED Maintenance Tips

The status is checked every day. You need a flashing black hourglass, which means that the device seems all set for the use of means. If you can not see a flashing black hourglass on the automated external defibrillator, you need this is a authorized person who will check your machine. A trained person must carry out these inspections a day.

The check must be made on a monthly basis, and this should be done by an AED coordinator. After an AED, the AED Coordinatorall the electrodes used to replenish the batteries, PC cards and gloves kit. The unused supplies must be tested to be the most intact and within expiration dates. Batteries must be replaced and a battery built-in test (BIT) before using the AED must be led back in operation - this is an important factor in the maintenance AED.

Automated External Defibrillator Maintenance Tips

You must make sure that the lid has no cracks or loose parts. AllDevice cable must not have any cracks, cuts or broken wires. The exterior and the plug must be cleaned and disinfected to prevent contamination with bacteria unnecessary. Cleaning of all AED units can be done. Take a look at the manual to find a suitable cleaning agent. Check the status indicator after each use to see if he is ready. Also check the power, the results of ECG, indicators, and if the voice or voice instructions still work. DoEnsure that the emergency AED kit contains all the necessary equipment for an operation. It 'very important that these devices are kept in good condition and are checked regularly so that no case will surprise you. There are also maintenance-free anti-epileptic drugs on the market.

The Law of the Good Samaritan and AED

If an AED before surgery, you must be willing to perform CPR, and must also be ready for the exposure of the blood. In most U.S. states, there are good faithPolitics, which operates in case of emergency intervention. This means that each person comes with an AED in an emergency under the laws of the Good Samaritan. So the person who resuscitation kit with an AED is not liable for injury or death could be the result of an AED intervention.

This is considered as unintentional injury and therefore the person who has not given the patient's life can not be legally liable. So in most U.S. states of goodSamaritan law provides protection for both prepared and trained AED users. However, the use of a reckless manslaughter because the AED and can sometimes end up with legal fees as a case in Virginia in June 2005. This gives us even more reasons for AED maintenance as an important task to consider.


AED Maintenance Tips

Coupon Spinning Schwinn Purchasing Step2 Wagon

Wednesday, September 14, 2011

How to use an Automated External Defibrillator (AED) - it's easy!

!±8± How to use an Automated External Defibrillator (AED) - it's easy!

An Automated External Defibrillator (AED) is a device to shake, a victim of sudden cardiac arrest can be reversed, and perhaps fatal disease and restore the heartbeat of a victim. In the first minutes of cardiac arrest, cardiac fibrillation (chaotic electrical activity) and can be corrected by an electrical discharge. In December 2005, the American Heart Association simplified assessment protocols to support a victim in sudden cardiac arrest. Now there is asimple analysis into two parts.

1 The victim does not respond when shaken and talking loudly.

2 The victim is not breathing.

If both criteria are met then Cardio Pulmonary Resuscitation (CPR) is initiated and an AED to the victim should be as soon as possible. AEDs vary in size, shape and color as part of marketing strategies for producers to distinguish between them. All antiepileptic drugs on the market has been authorized by the Food and Drug Administrationsafe and effective media machine. Not a doctor trained specifically for the user, which is designed undoubtedly nervous and anxious.

AEDs are verbal indications that, once I switched to start. These instructions are very easy to talk you through the simple steps of defibrillation. Some AEDs give detailed instructions on the steps of CPR and coverage. One of the first clues are on the pad (also called electrodes) on the victim's chest instead.The tablets in a sealed package and have already gelled with a conductive substance, very sticky. The package and the same measurements are often images that clearly show where they are. A pad is in the upper right chest just below the collarbone and the other goes to the left under the ribs. The heart is the center of the chest just left of the sternum. The bearings are positioned so that the shock travels from pad-pad actually inside the victim'sBody from the heart. An AED is a piece pad that offer a cross between the two pads is connected to more ease in positioning.

There are several special considerations before the pads of a victim. There should be a "training kit", with the EDA that the gloves, a razor, scissors, and contains a dry cloth.

1 If the victim has a lot of chest hair (especially if the skin is not visible) need to remove the excess. This takes about 10 secondswith a disposable razor only on areas where the pads must be applied.

2 Jewellery in the neck especially is that low in the chest area to be removed or put aside. Piercing should be left alone, regardless of their location. The swab should be placed at least an inch from the piercing.

3 A patch or patches of adhesive type patch on the chest, a meditation and should be removed and clean the area in front of the chemically cleaned.

4 If the victimChest is wet or sweaty, it should be dried before applying the pads.

5 If the victim has a pacemaker or a defibrillator inside (you will receive a lump or notice any visible scar) place the pad at least an inch away.

Once the pads are respected the victim's chest, the AED is a verbal signal to stop giving the consumer to touch the victim as it begins to automatically analyze the heart's electrical activity. If the AED interpret the hearts electrical activity is called ventricular fibrillation, said,the Savior, you press the flashing clearly shaken. There should be no physical contact with the victim during analysis and shock. Some AEDs automatically shock after the issuance of a notice orally.

Regardless of the outcome, all AEDs will instruct the rescuer, the CPR is administered immediately after a shock. American Heart Association protocol provides two minutes of CPR before the AED automatically re-analyzed and possibly advises another shock. ThisOrder of two minutes followed by shocking CPR should be continued until the victim to relive or emergency medical personnel take the e.

Sudden cardiac arrest is one of the most common causes of death that may occur without warning. Fortunately, automated external defibrillators are becoming increasingly common outside the hospital. CPR / AED training through various institutions, including the American Heart Association and the American Red Cross is available.


How to use an Automated External Defibrillator (AED) - it's easy!

!8!# Mini Digital Camera Sale

Friday, September 9, 2011

AED Plus configuration http://www.quickmedical.com/

Buyers Insinkerator Hot Water Dispensers Best Prices Garmin 405 Vs 405cx Shop Chain Chain Saw


Twitter Facebook Flickr RSS



Français Deutsch Italiano Português